  1. Jan 11, 2019 at 6:33 PM
    Kemosabe

    Kemosabe Little bitty life

    Joined:
    Apr 2, 2015
    Member:
    #152362
    Messages:
    6,200
    Gender:
    Male
    First Name:
    Louis
    Western Quebec, Canada
    Vehicle:
    2010, 2.7l, 4x4, M/T
    URD STS, Spidertrax spacers, AFE Pro dry
    You could have an electrician friend switch a breaker for a 20amp then change the outside plug for a 20 as well? Just brainstorming, since i'd rather you have a good plug than trying to weld and jump it, then start a fire in the pannel...
     
  2. Jan 11, 2019 at 6:33 PM
    Skierrichy

    Skierrichy MadRad

    Joined:
    Jun 10, 2018
    Member:
    #256051
    Messages:
    5,397
    Gender:
    Male
    First Name:
    Richard
    Willington
    Vehicle:
    2011 TRD
    To many, but never done
    :rofl::rofl::rofl:
    @EatSleepTacos u better get on thiso_O
     
  3. Jan 11, 2019 at 6:35 PM
    Redmann

    Redmann DILLIGAF

    Joined:
    Dec 30, 2016
    Member:
    #206119
    Messages:
    6,930
    Gender:
    Male
    First Name:
    Reds
    Philly
    Vehicle:
    2009 AC TRDOR
    Sup
     
  4. Jan 11, 2019 at 6:35 PM
    ovrlndkull

    ovrlndkull STUKASFK - HC4LIFE

    Joined:
    Jan 7, 2017
    Member:
    #206806
    Messages:
    37,791
    Gender:
    Male
    First Name:
    Skip
    Burlington, NC
    Vehicle:
    2005 DCLB Silver
    63s, XD Machete, Beat not Babied
    If he's using the dryer plug that's a 220 a std plug is only 110 so still short on power. Not sure if it's the same up canadian way but the wiring going to each of these is different. Today the 220 stuff is 4 wire and the 110 is only 3 also very differen awg wiring.
     
    Justanotherhemi likes this.
  5. Jan 11, 2019 at 6:44 PM
    EatSleepTacos

    EatSleepTacos [OP] Well-Known Member

    Joined:
    Mar 24, 2015
    Member:
    #151688
    Messages:
    59,628
    Gender:
    Male
    First Name:
    Randy
    West Valley, AZ
    Vehicle:
    2017 4Runner
    Extended with 700lbs. I’m so excited.
    I’d worry about the wiring in between being thick enough to handle the current. I feel like that’s how a house fire would start lol
    You made your own welding extension cord, right? Roughly what did it cost you?
    The 20A I use is the washer, so it’s 110. Dryer is 220 but I don’t mess with that.
     
  6. Jan 11, 2019 at 6:46 PM
    ovrlndkull

    ovrlndkull STUKASFK - HC4LIFE

    Joined:
    Jan 7, 2017
    Member:
    #206806
    Messages:
    37,791
    Gender:
    Male
    First Name:
    Skip
    Burlington, NC
    Vehicle:
    2005 DCLB Silver
    63s, XD Machete, Beat not Babied
    Nice!

    Got ya I thought you had a welder that used either 220 or 110
     
  7. Jan 11, 2019 at 7:01 PM
    Justanotherhemi

    Justanotherhemi Space Cowboy/Ninja

    Joined:
    Dec 7, 2016
    Member:
    #204297
    Messages:
    14,664
    First Name:
    Rick James
    Area 52 (because area 51 was full)
    Vehicle:
    Intelligent Life Exists
    That rock looks nice. Better than the beer really :anonymous:

    Havent you ever heard that you never get in between 2 girls fighting?

    I hate you for this. I was looking for the fair dust post amd you deleted it. :angrygirl:


    #I multiquote For @EatSleepTacos & his twerking stolen avatar
     
  8. Jan 11, 2019 at 7:02 PM
    Kemosabe

    Kemosabe Little bitty life

    Joined:
    Apr 2, 2015
    Member:
    #152362
    Messages:
    6,200
    Gender:
    Male
    First Name:
    Louis
    Western Quebec, Canada
    Vehicle:
    2010, 2.7l, 4x4, M/T
    URD STS, Spidertrax spacers, AFE Pro dry
    In theory, with a 3-12 wire you'd be safe for 20amps. But i think @Redmann or @Bocsy44 would be better than me to answer. But I think my 20 amp plug is wired with 10ga...
     
  9. Jan 11, 2019 at 7:05 PM
    Justanotherhemi

    Justanotherhemi Space Cowboy/Ninja

    Joined:
    Dec 7, 2016
    Member:
    #204297
    Messages:
    14,664
    First Name:
    Rick James
    Area 52 (because area 51 was full)
    Vehicle:
    Intelligent Life Exists
    Just put duck tape on it. Fixed
     
  10. Jan 11, 2019 at 8:11 PM
    08TRDOFFROAD

    08TRDOFFROAD Well-Known Member

    Joined:
    Nov 4, 2008
    Member:
    #10482
    Messages:
    4,387
    Gender:
    Male
    First Name:
    Dan
    Vehicle:
    21' Tundra Platinum & 08' TRD Offroad DCSB 4x4
    Bilstein 5100's w/front's set at 1.75", TRD exhaust, Colormatched grill, Illuminated 4wd selector switch, BAMF Bolt on Sliders w/kickout.
    12/2 is fine for 20 amp. That is how I wired my whole basement. 14/2 for 15 Amps. When I wired my 220 outlet in my garage for my compressor I ran 10/3 to a 30 amp breaker. For 220 runs, the longer the run, the heavier gauge wire you need to run.

    In reality, the quality of modern solid copper wire and the conductive properties of it, you could likely pull 20 Amps through 14/2...but I dont know if it's worth the risk.
     
    Skierrichy and Kemosabe[QUOTED] like this.
  11. Jan 11, 2019 at 8:13 PM
    Redmann

    Redmann DILLIGAF

    Joined:
    Dec 30, 2016
    Member:
    #206119
    Messages:
    6,930
    Gender:
    Male
    First Name:
    Reds
    Philly
    Vehicle:
    2009 AC TRDOR
    20 amp doesnt necessarily mean 110v. How its hooked up in the panel determines the volts. The amps are determined by a combination of wire size and the matching breaker.

    I didn't make an extension cord, but I DID make an adapter to plug in a tig welder to a gas generator. It consisted of a twist lock 30amp plug, 10/3 wire (4 conductors, black, red, white, and bare ground) and a 50amp 3 wire range receptacle. In the range recept, I combined the ground and the white.
    14 gauge wire = 15amps
    12 gauge wire = 20 amps
    10 gauge wire = 30 amps




    Amps are determined by the breaker. You need to make sure the wire is sized properly to handle the amps, otherwise :bananadead:



    Here's a pic of the adapter I made. Making your own extension cord should be easy.

    20180420_122004.jpg
     
  12. Jan 11, 2019 at 8:17 PM
    Redmann

    Redmann DILLIGAF

    Joined:
    Dec 30, 2016
    Member:
    #206119
    Messages:
    6,930
    Gender:
    Male
    First Name:
    Reds
    Philly
    Vehicle:
    2009 AC TRDOR
    The code says 80% of the amps should be on the circuit. So in reality, 80% of 15amps should pass thru a 14 gauge wire.

    You could have probably used 10/2 for your compressor. It likely didn't need a neutral. Neutrals are needed when devices that are being used have a need for 110 volts. I doubt the compressor had any kind of LED lights or anything like that?
     
    Skierrichy likes this.
  13. Jan 11, 2019 at 8:18 PM
    Redmann

    Redmann DILLIGAF

    Joined:
    Dec 30, 2016
    Member:
    #206119
    Messages:
    6,930
    Gender:
    Male
    First Name:
    Reds
    Philly
    Vehicle:
    2009 AC TRDOR
    That's not to say the wire cant HANDLE more amps, just that's what the code says.
     
    08TRDOFFROAD likes this.
  14. Jan 11, 2019 at 8:20 PM
    08TRDOFFROAD

    08TRDOFFROAD Well-Known Member

    Joined:
    Nov 4, 2008
    Member:
    #10482
    Messages:
    4,387
    Gender:
    Male
    First Name:
    Dan
    Vehicle:
    21' Tundra Platinum & 08' TRD Offroad DCSB 4x4
    Bilstein 5100's w/front's set at 1.75", TRD exhaust, Colormatched grill, Illuminated 4wd selector switch, BAMF Bolt on Sliders w/kickout.
    No leds or anything other than the motor running. Wired to a 4 prong dryer plug.
    IMG_20151109_083025793.jpg
    IMG_20151103_084827971.jpg
     
  15. Jan 11, 2019 at 8:26 PM
    08TRDOFFROAD

    08TRDOFFROAD Well-Known Member

    Joined:
    Nov 4, 2008
    Member:
    #10482
    Messages:
    4,387
    Gender:
    Male
    First Name:
    Dan
    Vehicle:
    21' Tundra Platinum & 08' TRD Offroad DCSB 4x4
    Bilstein 5100's w/front's set at 1.75", TRD exhaust, Colormatched grill, Illuminated 4wd selector switch, BAMF Bolt on Sliders w/kickout.
    Did I go too big?

    20190111_205802.jpg

    Or is there such a thing?
     
  16. Jan 11, 2019 at 9:53 PM
    Redmann

    Redmann DILLIGAF

    Joined:
    Dec 30, 2016
    Member:
    #206119
    Messages:
    6,930
    Gender:
    Male
    First Name:
    Reds
    Philly
    Vehicle:
    2009 AC TRDOR
    To further expound on what I said....

    Extension cords are generally made better than regular romex (pictured in the adapter I made). BUT SJ cord is rather expensive compared to romex. SJ cord has each conductor insulated and is stranded, with a better, more resistant to scrapes, coating. That being said, if you're going to use the extension cord only your welder, then I'd be ok with it. Just take care of it, dont snag it on shit. Roll it out when you need it and roll it back when your done.
     
  17. Jan 11, 2019 at 11:09 PM
    RobP62

    RobP62 NVR20LD

    Joined:
    Jun 4, 2017
    Member:
    #220718
    Messages:
    41,519
    Gender:
    Male
    First Name:
    Rob
    Street, Md.
    Vehicle:
    TTC Member #0125
    I think I paid $80 for mine :bananadead:

    Necessary evil though.

    Edit - I think this is it:

    https://m.lowes.com/pd/Utilitech-Pr...0-Volt-10-Gauge-Yellow-Generator-Cord/3191751

    I plug it into a male outlet that's wired to my breaker box in the house and then to the generator.

    And yes, I test the geni bi-annually and it's plugged into a trickle charger.

    I'm OCD like that.
     
    Last edited: Jan 11, 2019
    TaKoToy likes this.
  18. Jan 11, 2019 at 11:09 PM
    RobP62

    RobP62 NVR20LD

    Joined:
    Jun 4, 2017
    Member:
    #220718
    Messages:
    41,519
    Gender:
    Male
    First Name:
    Rob
    Street, Md.
    Vehicle:
    TTC Member #0125
    It's the perfect size!
     
  19. Jan 11, 2019 at 11:19 PM
    RobP62

    RobP62 NVR20LD

    Joined:
    Jun 4, 2017
    Member:
    #220718
    Messages:
    41,519
    Gender:
    Male
    First Name:
    Rob
    Street, Md.
    Vehicle:
    TTC Member #0125
    @Kemosabe Louis, you have a home made Prinsu?
     
    Kemosabe likes this.
  20. Jan 11, 2019 at 11:29 PM
    RobP62

    RobP62 NVR20LD

    Joined:
    Jun 4, 2017
    Member:
    #220718
    Messages:
    41,519
    Gender:
    Male
    First Name:
    Rob
    Street, Md.
    Vehicle:
    TTC Member #0125
    This FTMFW ^^^^^^^ :headbang:

    Once I replaced a live 20amp breaker in the box (no main) on the pole out behind the pool shed, standing on crunchy frozen ground. I told my wife to watch from the window, with the phone in her hand prepared to dial the last 1 just in case.....

    And yes "I do eat Fn Crayons"
     