Discussion in '3rd Gen. Tacomas (2016-2023)' started by IdeaMan, Jan 27, 2020.

  1. Jan 27, 2020 at 3:37 PM
    #1
    IdeaMan

    IdeaMan [OP] Well-Known Member

    Joined:
    Feb 16, 2018
    Member:
    #244608
    Messages:
    164
    Gender:
    Male
    First Name:
    Jim
    Fresno, CA
    Vehicle:
    Barcelona Red 2018 Toyota Tacoma SR DCSB 4x4
    Eibach Pro Truck Lift, Icon RXT Leaf Springs, LT255/80R17 Toyo ATIII, Body Armor Hiline Bumper w/OZ LED Light bar and Smittybuilt X20 Synthetic Winch, TRD Pro Skid plate, Shrockworks Sliders/steps, bed mat, some interior storage accessories, cell phone mount, and blacked out emblems.
    I understand you want the least resistance possible when wiring the winch. Is there any reason to switch the positive connection to the area circled in yellow or is it exactly the same as where I currently have it wired? Please correct me if I’m wrong, but I’m thinking it doesn’t matter and I put it in the current spot so I can still use the red, rubber cover as seen in pic 2.

    59A01054-ADB0-4760-AE86-C8766DFAA050.jpg

    B20011B9-8FC4-482D-8DF0-34A39ACE68F4.jpg
     
  2. Jan 27, 2020 at 3:39 PM
    #2
    PhenixFord

    PhenixFord Well-Known Member

    Joined:
    Aug 1, 2019
    Member:
    #300917
    Messages:
    1,215
    Gender:
    Male
    First Name:
    Randy
    Arkansas
    Vehicle:
    2019 MGM SR5 4WD DCSB
    Your fine where it is.

    Edit: Hope the fuse is close by?
     
    Skydvrr likes this.
  3. Jan 27, 2020 at 4:09 PM
    #3
    IdeaMan

    IdeaMan [OP] Well-Known Member

    Joined:
    Feb 16, 2018
    Member:
    #244608
    Messages:
    164
    Gender:
    Male
    First Name:
    Jim
    Fresno, CA
    Vehicle:
    Barcelona Red 2018 Toyota Tacoma SR DCSB 4x4
    Eibach Pro Truck Lift, Icon RXT Leaf Springs, LT255/80R17 Toyo ATIII, Body Armor Hiline Bumper w/OZ LED Light bar and Smittybuilt X20 Synthetic Winch, TRD Pro Skid plate, Shrockworks Sliders/steps, bed mat, some interior storage accessories, cell phone mount, and blacked out emblems.
    What fuse? Just wired it direct to battery like shown in the instructions.
     
    GreyBaldTaco and Ch78 like this.
  4. Jan 27, 2020 at 4:10 PM
    #4
    PhenixFord

    PhenixFord Well-Known Member

    Joined:
    Aug 1, 2019
    Member:
    #300917
    Messages:
    1,215
    Gender:
    Male
    First Name:
    Randy
    Arkansas
    Vehicle:
    2019 MGM SR5 4WD DCSB
    May need a second opinion?
     
    Cudgel likes this.
  5. Jan 27, 2020 at 4:13 PM
    #5
    Gregw138

    Gregw138 Well-Known Member

    Joined:
    Jan 19, 2019
    Member:
    #279902
    Messages:
    1,368
    Gender:
    Male
    First Name:
    Greg
    NY
    Vehicle:
    2019 TRD Off Road DCSB 2016 Lexus ES350 2009 Lexus ES350
    WAY TOO MANY
  6. Jan 27, 2020 at 4:54 PM
    #6
    theesotericone

    theesotericone Well-Known Member

    Joined:
    Jul 27, 2018
    Member:
    #260800
    Messages:
    12,083
    Gender:
    Male
    Bishop CA
    I winch does not need to be fused. That kit linked above is NOT a fuse. It's a disconnect using a solenoid. IMO, you should absolutely run a disconnect. Be it the one linked or a Blue Sea.

    EDIT: Actually just get a Blue Sea rated to 600A intemittent. I have no idea what the rating on that WARN Solenoid included in that kit is. Nor do I care to look. lol
     
    GreyBaldTaco likes this.
  7. Jan 27, 2020 at 4:59 PM
    #7
    theesotericone

    theesotericone Well-Known Member

    Joined:
    Jul 27, 2018
    Member:
    #260800
    Messages:
    12,083
    Gender:
    Male
    Bishop CA
    Have you ever replaced the main starter lead? There's no fuse. The wire is over sized for the load. Using an ECM as a fuse will end really, really badly for the ECM. lol
     
  8. Jan 27, 2020 at 5:01 PM
    #8
    JoeCOVA

    JoeCOVA Well-Known Member

    Joined:
    Nov 15, 2016
    Member:
    #202463
    Messages:
    9,652
    First Name:
    Joe
    Colorado Springs
    Vehicle:
    Ford F350, Lexus RX450h, FZJ80, Jeep YJ
    My Warn draws 460amps....a fuse would be impractical.
     
    toofast4u752 and theesotericone like this.
  9. Jan 27, 2020 at 5:02 PM
    #9
    PhenixFord

    PhenixFord Well-Known Member

    Joined:
    Aug 1, 2019
    Member:
    #300917
    Messages:
    1,215
    Gender:
    Male
    First Name:
    Randy
    Arkansas
    Vehicle:
    2019 MGM SR5 4WD DCSB
    Modern electronics are more sophisticated than that. Now-a-days, you don't have to have mechanical protection.
     
  10. Jan 27, 2020 at 5:02 PM
    #10
    tacomarin

    tacomarin ig: @travelswithchubbs

    Joined:
    Sep 15, 2017
    Member:
    #230087
    Messages:
    1,830
    Gender:
    Male
    First Name:
    Steve
    Bay Area
    Vehicle:
    2018 DCLB TRD OR
    Prinsu Cab and Top Rack VO Drifter LED Interior, License Plate, and Reverse Lights Huskyliner Weather Beater floor mats Salex Center Console Organizers 35% Front/15% Rear Tint Debadged and De-stickered Anytime Front and Rear Cameras Brute force front bumper BAMF HC Dual swing out 285/75r17 BFG KO2 Front: ADS 2.5, EXT, RR, Clickers Rear: OME Dakar HD, ADS 2.5, EXT, RR, Clickers Stainless steel brake lines (+4 in rear) Wheeler's Offroad Superbumps Front and Rear Wheeler's Offroad U-bolt flip ECGS CV Axle Bushing SCS Stealth 6 17x8.5 wheels, matte dark bronze
    Lol. This thread. :bananadead:

    An interrupter kit is the "safest" option. Turn off the winch cable when you aren't using it so it doesn't potentially wear through the insulation and short out.

    Most people don't run fuses on winch cables because it's a huge draw. It's going to be somewhere between 0 and 500 A depending on how hard of a pull you have. So what do you size the fuse to? 500 A? 600A to be safe? What's it going to draw when it shorts? Probably less than 500A which means your fuse isn't going to do anything.

    IMO your best bet is to protect the cable, secure it well, carry a fire extinguisher, and get an interrupter to keep it turned off when you're not using it.
     
  11. Jan 27, 2020 at 5:03 PM
    #11
    PhenixFord

    PhenixFord Well-Known Member

    Joined:
    Aug 1, 2019
    Member:
    #300917
    Messages:
    1,215
    Gender:
    Male
    First Name:
    Randy
    Arkansas
    Vehicle:
    2019 MGM SR5 4WD DCSB
    But not constantly. Just Start up, right?
     
  12. Jan 27, 2020 at 5:04 PM
    #12
    theesotericone

    theesotericone Well-Known Member

    Joined:
    Jul 27, 2018
    Member:
    #260800
    Messages:
    12,083
    Gender:
    Male
    Bishop CA
    Wrong. It's a constant pull that gets smaller as more line gets on the drum.


    Only on main power leads, I guess? lol
     
    michaeln likes this.
  13. Jan 27, 2020 at 5:08 PM
    #13
    PhenixFord

    PhenixFord Well-Known Member

    Joined:
    Aug 1, 2019
    Member:
    #300917
    Messages:
    1,215
    Gender:
    Male
    First Name:
    Randy
    Arkansas
    Vehicle:
    2019 MGM SR5 4WD DCSB
    Fuse is usually determined by multiplying 125% of full load. Motor fuses are usually Slow Blow. So they can hold without blowing through the high current spikes.

    A "direct short" will generate current well above the fuse rating. A chafing wire "may" carry a load until it becomes a direct short.

    I personally would go the fuse route just for convenience. A bare minimum there should be a means of disconnecting.
     
    AKGSD likes this.
  14. Jan 27, 2020 at 5:18 PM
    #14
    Georgia Native

    Georgia Native Well-Known Member

    Joined:
    May 12, 2018
    Member:
    #253296
    Messages:
    309
    Vehicle:
    4x4 DCLB 2017 SR5, 2019 4runner Offroad, 2021 SR Access Cab
  15. Jan 27, 2020 at 5:21 PM
    #15
    JoeCOVA

    JoeCOVA Well-Known Member

    Joined:
    Nov 15, 2016
    Member:
    #202463
    Messages:
    9,652
    First Name:
    Joe
    Colorado Springs
    Vehicle:
    Ford F350, Lexus RX450h, FZJ80, Jeep YJ
    That’s under load man.
     
  16. Jan 27, 2020 at 5:33 PM
    #16
    JoeCOVA

    JoeCOVA Well-Known Member

    Joined:
    Nov 15, 2016
    Member:
    #202463
    Messages:
    9,652
    First Name:
    Joe
    Colorado Springs
    Vehicle:
    Ford F350, Lexus RX450h, FZJ80, Jeep YJ
    There are little to no cases of issues with winches and no fuse or disconnect. Sure you can burn up your winch wiring but it's exceptionally rare. The Warn on my truck is 15 years old and I have another on my Jeep that is 10 years old and never ran a fuse or disconnect, no issues.

    Sure a fuse or disconnect is a risk mitigation but the risk is already low.. We all transfer risk through insurance.
     
  17. Jan 27, 2020 at 5:36 PM
    #17
    JoeCOVA

    JoeCOVA Well-Known Member

    Joined:
    Nov 15, 2016
    Member:
    #202463
    Messages:
    9,652
    First Name:
    Joe
    Colorado Springs
    Vehicle:
    Ford F350, Lexus RX450h, FZJ80, Jeep YJ
    There is risk but it's very low risk. Risk is actually transferred to insurance companies, if your car burns down they cut a check. We as consumers aren't actually accepting any risk.
     
  18. Jan 27, 2020 at 5:36 PM
    #18
    PhenixFord

    PhenixFord Well-Known Member

    Joined:
    Aug 1, 2019
    Member:
    #300917
    Messages:
    1,215
    Gender:
    Male
    First Name:
    Randy
    Arkansas
    Vehicle:
    2019 MGM SR5 4WD DCSB
    I agree that it's rare. Arkansas is a BIG Off-Road state. I have seen people burn them down.

    Maybe I am a little OCD because of my electrical background. That doesn't make me wrong though.
     
    AKGSD and Sclarpepplar like this.
  19. Jan 27, 2020 at 5:37 PM
    #19
    JoeCOVA

    JoeCOVA Well-Known Member

    Joined:
    Nov 15, 2016
    Member:
    #202463
    Messages:
    9,652
    First Name:
    Joe
    Colorado Springs
    Vehicle:
    Ford F350, Lexus RX450h, FZJ80, Jeep YJ
    Personally I dont think anyone is wrong, it's simply a risk factor for people to consider and mitigate, avoid, transfer or accept.
     
    johntoyota and theesotericone like this.
  20. Jan 27, 2020 at 5:37 PM
    #20
    theesotericone

    theesotericone Well-Known Member

    Joined:
    Jul 27, 2018
    Member:
    #260800
    Messages:
    12,083
    Gender:
    Male
    Bishop CA
    Right. Warn has a double solenoid system. If one fails the winch won't pull in or out. Most other manufactures rely on a single solenoid. If one of those fails it can be really bad. I run a 12K Engo. I ran a Blue Sea disconnect just to make sure it's powered off until I need it. It's just piece of mind and it still cost me way less then a Warn. lol
     