Brass compression fittings on PVC air line?

Discussion in 'Garage / Workshop' started by bigmooze, Nov 2, 2010.

  1. Nov 2, 2010 at 5:03 PM
    #1
    bigmooze

    bigmooze [OP] Well-Known Member

    Joined:
    Jan 10, 2009
    Member:
    #12437
    Messages:
    810
    Gender:
    Male
    First Name:
    Richard
    Belle River, ON
    Vehicle:
    2009 4x4 access cab SR5
    Bilstein 5100's all round (0" up front with stock springs), 265/75/16 Goodyear Wrangler Duratracs, K&N 63 Series Aircharger Kit, Flowmaster Super 44 Muffler, Delta Champion Toolbox, fog lights, back-up lights, Sirius satellite radio with PA15-TOY, Midland 1001z CB radio with 2' Firestik II antenna, Weathertech floor mats, AVS sill protectors, Marathon SuperHides Seatcovers (Universal Digital Camo), trimmed front mud flaps, Viair 20005 OBA, Warn W650D driving lights and W650F fog lights on N-Fab light bar, Hi-Lift X-treme jack with off road accessories, TracRac "TracONE" system
    Need some advice from the TW community:

    Can brass compression fittings be used to couple 1/4" diameter PVC air line, such as that used for air bags?

    For me, these are more readily available than the push-to-connect types.
    The lines could be pressurized up to 150 psi (bags will not be operated at this pressure, however).
     
  2. Nov 3, 2010 at 2:28 AM
    #2
    bigmooze

    bigmooze [OP] Well-Known Member

    Joined:
    Jan 10, 2009
    Member:
    #12437
    Messages:
    810
    Gender:
    Male
    First Name:
    Richard
    Belle River, ON
    Vehicle:
    2009 4x4 access cab SR5
    Bilstein 5100's all round (0" up front with stock springs), 265/75/16 Goodyear Wrangler Duratracs, K&N 63 Series Aircharger Kit, Flowmaster Super 44 Muffler, Delta Champion Toolbox, fog lights, back-up lights, Sirius satellite radio with PA15-TOY, Midland 1001z CB radio with 2' Firestik II antenna, Weathertech floor mats, AVS sill protectors, Marathon SuperHides Seatcovers (Universal Digital Camo), trimmed front mud flaps, Viair 20005 OBA, Warn W650D driving lights and W650F fog lights on N-Fab light bar, Hi-Lift X-treme jack with off road accessories, TracRac "TracONE" system
    Bump, anyone?
     
  3. Nov 3, 2010 at 5:57 AM
    #3
    macgyver

    macgyver Well-Known Member

    Joined:
    Aug 14, 2009
    Member:
    #21173
    Messages:
    3,577
    Gender:
    Male
    First Name:
    Brad
    Canton, GA
    Vehicle:
    '13 Tundra double cab SR5 4x4
    What will be the normal pressure?

    Brass compression fittings are used all the time in household plumbing.
     
  4. Nov 3, 2010 at 6:14 AM
    #4
    OH-MAN

    OH-MAN Well-Known Member

    Joined:
    Apr 23, 2009
    Member:
    #16324
    Messages:
    2,305
    Gender:
    Male
    First Name:
    Steve
    Sunny Az.
    Vehicle:
    10 4X4 O.R. White
    TRD skid painted black,
    You will need the correct compression farrels and inserts to keep the plastic from crushing.
    That being said
    i do not like PVC used in compressed air systems.
    Many do and have no problems, BUT not good.
     
  5. Nov 3, 2010 at 6:14 AM
    #5
    xJuice

    xJuice My spoon is too Big!

    Joined:
    Oct 24, 2007
    Member:
    #3208
    Messages:
    9,891
    Gender:
    Male
    First Name:
    Josh
    N. Texas
    Vehicle:
    19 Tundra MGM
    TRD Front & Rear Sway Bar, TRD Pro LED Headlights, Undercover SE, Rear diff. Relocate, console organizer, debadged, color matched handles, mirror caps, and grill
    I've seen people use both types of fittings on air bag setups.
     
  6. Nov 3, 2010 at 6:16 AM
    #6
    macgyver

    macgyver Well-Known Member

    Joined:
    Aug 14, 2009
    Member:
    #21173
    Messages:
    3,577
    Gender:
    Male
    First Name:
    Brad
    Canton, GA
    Vehicle:
    '13 Tundra double cab SR5 4x4
    Whats the matter...are you skurred?
     
  7. Nov 3, 2010 at 6:21 AM
    #7
    98tacoma27

    98tacoma27 is going full "SANDWICH" Moderator

    Joined:
    Dec 18, 2008
    Member:
    #11714
    Messages:
    67,723
    Gender:
    Male
    First Name:
    Ben
    Not Beech Creek
    Vehicle:
    05 Tundra SR5 (+295k AND COUNTING), 2006 F350 King Ranch 6.0L
    Some stuff. Not a lot, just some.
    X2 It's not PVC pipe, it's PVC air line. It's designed for air pressure. I've probably got thousands of feet of it out on my manufacturing floor.
     
  8. Nov 3, 2010 at 6:26 AM
    #8
    OH-MAN

    OH-MAN Well-Known Member

    Joined:
    Apr 23, 2009
    Member:
    #16324
    Messages:
    2,305
    Gender:
    Male
    First Name:
    Steve
    Sunny Az.
    Vehicle:
    10 4X4 O.R. White
    TRD skid painted black,
    YES indeed, PVC does not like hydrocarons ( oil from compressor or ? )
    It also becomes very brittle in sunlight or UV rays.

    As the temp goes up the pressure rating drop very quickly.
    Compressors produce very hot air and many introduce oil into the compressed air.
    Pipe can fail and schrapnel will fill the air.

    Air lines for bags are a different plastic I think.
     
  9. Nov 3, 2010 at 6:30 AM
    #9
    Southern01Taco

    Southern01Taco Well-Known Member

    Joined:
    Jul 20, 2010
    Member:
    #40457
    Messages:
    1,954
    Gender:
    Male
    First Name:
    Sean
    Holden, La
    Vehicle:
    01 V6 4x4 Xtra Cab SR5
    You can use them. Some people prefer to use compression fittings over push to connect because they claim it gets a better seal. On my s10 I have used both compression and push to connect and they both work good.
     
  10. Nov 3, 2010 at 6:46 AM
    #10
    bigmooze

    bigmooze [OP] Well-Known Member

    Joined:
    Jan 10, 2009
    Member:
    #12437
    Messages:
    810
    Gender:
    Male
    First Name:
    Richard
    Belle River, ON
    Vehicle:
    2009 4x4 access cab SR5
    Bilstein 5100's all round (0" up front with stock springs), 265/75/16 Goodyear Wrangler Duratracs, K&N 63 Series Aircharger Kit, Flowmaster Super 44 Muffler, Delta Champion Toolbox, fog lights, back-up lights, Sirius satellite radio with PA15-TOY, Midland 1001z CB radio with 2' Firestik II antenna, Weathertech floor mats, AVS sill protectors, Marathon SuperHides Seatcovers (Universal Digital Camo), trimmed front mud flaps, Viair 20005 OBA, Warn W650D driving lights and W650F fog lights on N-Fab light bar, Hi-Lift X-treme jack with off road accessories, TracRac "TracONE" system
    Thanks for all the replies, I'll see how it works out and report back.
     
  11. Dec 14, 2010 at 9:20 PM
    #11
    R6Racer

    R6Racer Member

    Joined:
    Dec 12, 2010
    Member:
    #47589
    Messages:
    17
    Gender:
    Male
    First Name:
    Steve
    Ontario Canada
    Vehicle:
    03 PreRunner
    PVC & Air pressure lines = EXTREMELY BAD
    Don't do it.
    PVC is NOT designed to hold compressed air.
    Any one who has told you it's OK to use for air is badly mistaken!
    There are lots of materials you can use for air lines but PVC is one to most definitely stay away from! If you have it in, take it out!!!
    There is no such thing as PVC air line.

    Steve
     
  12. Dec 14, 2010 at 9:44 PM
    #12
    R6Racer

    R6Racer Member

    Joined:
    Dec 12, 2010
    Member:
    #47589
    Messages:
    17
    Gender:
    Male
    First Name:
    Steve
    Ontario Canada
    Vehicle:
    03 PreRunner
  13. Dec 15, 2010 at 8:21 AM
    #13
    98tacoma27

    98tacoma27 is going full "SANDWICH" Moderator

    Joined:
    Dec 18, 2008
    Member:
    #11714
    Messages:
    67,723
    Gender:
    Male
    First Name:
    Ben
    Not Beech Creek
    Vehicle:
    05 Tundra SR5 (+295k AND COUNTING), 2006 F350 King Ranch 6.0L
    Some stuff. Not a lot, just some.

    We are talking tubing, not pipe. You're comparing apples to oranges.

    [​IMG]

    [​IMG]

    [​IMG]
     
    This site contains affiliate links for which the site may be compensated.
    #13
  14. Dec 15, 2010 at 8:36 AM
    #14
    Janster

    Janster Old & Forgetful

    Joined:
    Mar 25, 2007
    Member:
    #1138
    Messages:
    14,339
    Gender:
    Female
    First Name:
    Jandy
    Lancaster, PA
    Vehicle:
    2016 GMC Canyon SLT w/ LineX and....
    we have PVC pipe running off our compressor in our basement and its routed under the floors and into the walls to our garage. Haven't had a problem in 5+ years of having it installed. Our system is 125lbs or less.

    I wouldn't use the brass comprssion fittings (with furls,etc) on PVC.

    Use regular threaded pipe fittings, and quick disconnects (if possible). Nothing wrong with the nylon quick pushloc fittings.
     
  15. Dec 15, 2010 at 8:43 AM
    #15
    Jigzor

    Jigzor Well-Known Member

    Joined:
    May 19, 2009
    Member:
    #17413
    Messages:
    3,072
    Gender:
    Male
    Pennsylvania
    Vehicle:
    20 Gladiator Rubicon
    Steersmarts Draglink, Tie rod, Track Bar
    I don't think people understand Ben, try another approach..

    Option #1 above, is what is used at work. We have miles of it on reels.
     
    This site contains affiliate links for which the site may be compensated.
    #15
  16. Dec 15, 2010 at 8:45 AM
    #16
    98tacoma27

    98tacoma27 is going full "SANDWICH" Moderator

    Joined:
    Dec 18, 2008
    Member:
    #11714
    Messages:
    67,723
    Gender:
    Male
    First Name:
    Ben
    Not Beech Creek
    Vehicle:
    05 Tundra SR5 (+295k AND COUNTING), 2006 F350 King Ranch 6.0L
    Some stuff. Not a lot, just some.

    Can't, I keep losing brain cells.
     
  17. Dec 15, 2010 at 4:07 PM
    #17
    R6Racer

    R6Racer Member

    Joined:
    Dec 12, 2010
    Member:
    #47589
    Messages:
    17
    Gender:
    Male
    First Name:
    Steve
    Ontario Canada
    Vehicle:
    03 PreRunner
    OOPS
    Sorry , my mistake! :sorry:

    Had a friend get hurt when a PVC pipe that was being used as an air line blew. He was almost 40 feet away & he ended up with a few stitches from it. Could have been MUCH worse! Janster the system that injured my buddy was only 130psi!
    Wouldn't wish that on anyone.

    Steve
     
    This site contains affiliate links for which the site may be compensated.