ign1 #2 fuse keeps blowing

Discussion in '2nd Gen. Tacomas (2005-2015)' started by scanman, Jun 27, 2023.

  1. Jun 27, 2023 at 6:38 PM
    #1
    scanman

    scanman [OP] Member

    Joined:
    Jun 27, 2023
    Member:
    #427769
    Messages:
    13
    Gender:
    Male
    Vehicle:
    2015 double cab 4x4
    I recently bought a 2015 tacoma. About 2 hours into the 6 hour drive the ign1 #2 fuse blew and we lost a/c, power windows, and the airbag light, traction control light, and a few other warning lights came on. I am sure all the warning lights are from all the stuff that was connected to ign1 #2 fuse. We replaced the fuse and everything went back to normal but now everytime we turn the blower selector on the fuse pops instantly. Weird thing to me is that if I just turn the truck key to on without starting truck I can then turn the blower motor on lo, med, and high and it will run just fine without popping the fuse. So in my mind that would eliminate the blower selector, blower motor and blower motor resistor from being the problem. If anyone knows where to look next, I would greatly appreciate the advice.
     
  2. Jun 27, 2023 at 7:00 PM
    #2
    Dm93

    Dm93 Test Don't Guess

    Joined:
    Mar 3, 2015
    Member:
    #150066
    Messages:
    12,874
    Gender:
    Male
    Texas
    Vehicle:
    2014 DC OR 6spd 4x4
    Predator tube steps, Ranch Hand grill guard, Magnaflow CatBack exhaust, Toyota tool box & bed mat, 2LO Module by @Up2NoGood, Rearview Compass/Temp Mirror, Tune by @JustDSM.
    Unplug your A/C compressor and see if it still pops with the A/C on, if it doesn't then your A/C clutch is shorted. If it still does then you have a shorted wire going to the A/C compressor.
     
  3. Jun 27, 2023 at 7:27 PM
    #3
    scanman

    scanman [OP] Member

    Joined:
    Jun 27, 2023
    Member:
    #427769
    Messages:
    13
    Gender:
    Male
    Vehicle:
    2015 double cab 4x4
    unplugged the ac compressor and it still popped when turning on the blower motor. I will try to chase down the wires and look at them tomorrow when I have more light. Would it still be one of those 2 if it pops even without the ac button selected? Thanks
     
  4. Jun 27, 2023 at 7:33 PM
    #4
    Dm93

    Dm93 Test Don't Guess

    Joined:
    Mar 3, 2015
    Member:
    #150066
    Messages:
    12,874
    Gender:
    Male
    Texas
    Vehicle:
    2014 DC OR 6spd 4x4
    Predator tube steps, Ranch Hand grill guard, Magnaflow CatBack exhaust, Toyota tool box & bed mat, 2LO Module by @Up2NoGood, Rearview Compass/Temp Mirror, Tune by @JustDSM.
    I don't see what else it could be based on your symptom description, it feeds alot of stuff but since you say it only blows with the blower on and engine running I would think it would have to be in the A/C circuit.
     

    Attached Files:

    Steves104x4 likes this.
  5. Jun 27, 2023 at 7:38 PM
    #5
    Bishop84

    Bishop84 Well-Known Member

    Joined:
    Dec 17, 2015
    Member:
    #172494
    Messages:
    11,710
    Gender:
    Male
    I would think clutch circuit as well, I'd start by removing the MG CLT relay out (if this works, its a wiring short between relay and clutch), see if it pops, then if it has it CDS FAN relay.

    For giggles I would 100% check the connector to the resistor. It's the big one by the blower motor by the passenger foot well.
     
    Dm93 likes this.
  6. Jun 27, 2023 at 8:34 PM
    #6
    scanman

    scanman [OP] Member

    Joined:
    Jun 27, 2023
    Member:
    #427769
    Messages:
    13
    Gender:
    Male
    Vehicle:
    2015 double cab 4x4
    Removing the mg-clt relay worked and it does not pop the fuse now when turning on blower. Forgive my ignorance, I am guessing that means it is either the mag clutch or the wiring going to it causing the issue with relay in?
     
  7. Jun 27, 2023 at 8:39 PM
    #7
    Dm93

    Dm93 Test Don't Guess

    Joined:
    Mar 3, 2015
    Member:
    #150066
    Messages:
    12,874
    Gender:
    Male
    Texas
    Vehicle:
    2014 DC OR 6spd 4x4
    Predator tube steps, Ranch Hand grill guard, Magnaflow CatBack exhaust, Toyota tool box & bed mat, 2LO Module by @Up2NoGood, Rearview Compass/Temp Mirror, Tune by @JustDSM.
    That would seem to be the case.
    It's going to be a Violet wire.
     
    Steves104x4 likes this.
  8. Jun 27, 2023 at 9:49 PM
    #8
    scanman

    scanman [OP] Member

    Joined:
    Jun 27, 2023
    Member:
    #427769
    Messages:
    13
    Gender:
    Male
    Vehicle:
    2015 double cab 4x4
    Thanks to all that replied. I really appreciate the wisdom.
     