Ask a Plumber.

Discussion in 'Off-Topic Discussion' started by Rusty 06 4x4, Dec 27, 2011.

  1. Mar 22, 2012 at 10:57 AM
    #321
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    What type of sleeve would you suggest? Something to keep the copper isolated from the concrete/cement?
    thanks
     
  2. Mar 23, 2012 at 2:23 PM
    #322
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Did some research online, found a site suggesting using 1 1/2" pvc cemented to the wall. Then run the copper through the pvc, plugging it up with plumbers putty on both ends. Sound ok?
     
  3. Mar 23, 2012 at 2:51 PM
    #323
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    Sounds good....any time. U penetrate a wall you should use a sleve.....and use hydrolic cement to fill gaps....it expands as it dries..doesn't shirnk...mthen some typew of rubberiezed water proofing on exterior foundation wall
     
  4. Apr 9, 2012 at 4:51 PM
    #324
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Ok, I've got the permit in hand to replace the main!

    Couple of questions. I've been talked into up sizing the main to 1", then I'll reduce it down to 3/4" at the meter. Makes sense in case I want to install a 12 person hot tub in the future, or install a shower for each of my 4.5 lady friends....I'm living large...

    We are going to run copper, I'm guessing type K is worth the ~ 20%
    increase in cost?

    For the main inside shutoff, will use a 1" nibco full port valve. Pro's and cons of soldered versus threaded? I'm guessing the soldered are cheaper, and I'm leaning towards threaded. Seems to make more sense somehow.....

    Thanks, soon to be digging.....
     
  5. Apr 9, 2012 at 5:08 PM
    #325
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    no diffecence....mabye the sweat valve will have less friction....
     
  6. May 4, 2012 at 3:55 PM
    #326
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    I'm finally started on my first of many plumbing projects (replacing the water main). Just finished digging out the line under my porch, that was interesting......

    DSC02225 (Large).jpg
    DSC02230 (Large).jpg
     
  7. May 4, 2012 at 4:35 PM
    #327
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    DID U FIND HOFFA
     
  8. May 4, 2012 at 6:27 PM
    #328
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    No such luck, but I'll let you know when I find that treasure chest....About 4' down I did find evidence of an old lave tube...Check out this photo.

    DSC02238 (Large).jpg
     
  9. May 4, 2012 at 6:44 PM
    #329
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    :cool:
     
  10. May 13, 2012 at 2:53 PM
    #330
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    We just finished up the excavation, wow that was fun......Tomorrow we run the new copper!

    DSC02267 (Large).jpg
     
  11. May 13, 2012 at 2:59 PM
    #331
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    I'm to old for this shit.....lol

    The first rule is..........

    DSC02260 (Large).jpg
    DSC02262 (Large).jpg
     
  12. May 13, 2012 at 3:13 PM
    #332
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Gotta mark my territory......:rolleyes:
     
  13. May 13, 2012 at 9:15 PM
    #333
    acdronin

    acdronin Well-Known Member

    Joined:
    Dec 2, 2010
    Member:
    #47036
    Messages:
    19,635
    Gender:
    Male
    .
    That's a good lookin trench man
     
  14. May 14, 2012 at 9:25 AM
    #334
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Thanks, for all the good advice. And check it out, we be in business :)

    DSC02218 (Large).jpg
    DSC02290 (Large).jpg
    DSC02296 (Large).jpg
     
  15. May 14, 2012 at 9:31 AM
    #335
    xJuice

    xJuice My spoon is too Big!

    Joined:
    Oct 24, 2007
    Member:
    #3208
    Messages:
    9,902
    Gender:
    Male
    First Name:
    Josh
    N. Texas
    Vehicle:
    19 Tundra MGM
    TRD Front & Rear Sway Bar, TRD Pro LED Headlights, Undercover SE, Rear diff. Relocate, console organizer, debadged, color matched handles, mirror caps, and grill
    Looks much better. good job
     
  16. May 14, 2012 at 9:39 AM
    #336
    acdronin

    acdronin Well-Known Member

    Joined:
    Dec 2, 2010
    Member:
    #47036
    Messages:
    19,635
    Gender:
    Male
    .
    That is exactly the way that I would have mounted and plumbed that, good work!
     
  17. May 15, 2012 at 8:12 AM
    #337
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Thanks I had a plumber handle the assembly. Material and labor ended up costing me $1000 for the entire job. Most of that was the copper, no surprise there.

    So now I'm moving forward on the rest of this little project. Will be putting in a new direct vent water heater, radiant in the slab and a bathroom.

    Currently I'm looking at grinder pumps, this one in particular. It is expensive, but I'm not sure this is an area to go cheap on.
    It's a self contained, drop in unit. What do you think?
    http://www.deanbennett.com/zoeller-915-sewage-grinder-package.htm

    Thanks,
    Steve
     
  18. May 15, 2012 at 8:17 AM
    #338
    acdronin

    acdronin Well-Known Member

    Joined:
    Dec 2, 2010
    Member:
    #47036
    Messages:
    19,635
    Gender:
    Male
    .
    I have zero experience with grinder pumps, I never see them out here
     
  19. May 15, 2012 at 8:27 AM
    #339
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    LOOKING GREAT
    LOOKS GOOD.....AS LONG AS THE PUMP IS SERVICABLE YOUR IN BUSSINESS.....
     
  20. May 15, 2012 at 9:21 AM
    #340
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Awesome, I'm looking at a two different Bradford and white water heaters.

    http://www.pexsupply.com/Bradford-W...Energy-Saver-Residential-Water-Heater-Nat-Gas
    This model weighs 330 lbs, has lower btu input and less insulation. Yet costs a few hundred more than this model. http://www.pexsupply.com/Bradford-W...Energy-Saver-Residential-Water-Heater-Nat-Gas

    Any thoughts or suggestions? Thanks.
     

Products Discussed in