  1. Jun 11, 2012 at 8:38 PM
    #381
    acdronin

    acdronin Well-Known Member

    Joined:
    Dec 2, 2010
    Member:
    #47036
    Messages:
    19,635
    Gender:
    Male
    .
    that pipe may be too small to run a camera down, you said the house is on a slab? So no basement to look in for a prv, guess it's time to dig up the main, I would start at the house and work back towards the meter for three or four feet, if it's not there then i would do the same from the meter towards the house, if that's not it, then dig the whole damn thing up. Hope to god it isn't buried in the slab, shouldn't be though.
     
  2. Jun 12, 2012 at 6:52 AM
    #382
    Superdavert

    Superdavert Well-Known Member

    Joined:
    Feb 8, 2011
    Member:
    #50767
    Messages:
    267
    Gender:
    Male
    First Name:
    Dave
    Athens, Ga
    Vehicle:
    '09 TRD Sport DC SB
    MB Legacy wheels 285/70 17 BFG KO2s ProComp 2" leveling kit, Foglight anytime mod, Sockmonkey TRD Sport bedside decals, Extang Trifecta tonneau cover, Toyota bed extender, Aries black nerf bars, Pop & Lock
    It wouldn't surprise me if it was in the slab. The builder of the subdivision did things half a$$ed. The neighbors I've talked to have had found things that weren't properly done over the years.
     
  3. Jun 13, 2012 at 12:41 PM
    #383
    Enigmaaron

    Enigmaaron All your soul are belong to us

    Joined:
    Jul 6, 2009
    Member:
    #19337
    Messages:
    5,305
    Gender:
    Male
    PA
    Vehicle:
    1st gen superiority
    So I plan to replace the connections for the water heater with braided stainless hose connections. Looks like I can get either FPT x FPT or MPT x FPT. I know the heater will have MPT but what about the other end? Is there a standard to use on the water line connection side or does it not matter? I'm replacing the adapters (not trying to guess what I have), just want to know if there's a standard at all.
     
  4. Jul 28, 2012 at 7:22 AM
    #384
    Rusty 06 4x4

    Rusty 06 4x4 [OP] NBHNC

    Joined:
    Sep 26, 2011
    Member:
    #64142
    Messages:
    2,191
    Gender:
    Male
    First Name:
    Rusty
    West Georgia
    Vehicle:
    2006 4x4 Tacoma TRD DCSB
    should just be a 3/4 inch male adapter on the other end as well
     
  5. Jul 28, 2012 at 7:24 AM
    #385
    Rusty 06 4x4

    Rusty 06 4x4 [OP] NBHNC

    Joined:
    Sep 26, 2011
    Member:
    #64142
    Messages:
    2,191
    Gender:
    Male
    First Name:
    Rusty
    West Georgia
    Vehicle:
    2006 4x4 Tacoma TRD DCSB
    I have seen them buried as well after 20 years of plumbing you have kind of seen it all but usually when its buried its really close the meter
     
  6. Jul 28, 2012 at 9:11 AM
    #386
    neonlazer

    neonlazer Mechanically Goofy

    Joined:
    Oct 17, 2011
    Member:
    #65333
    Messages:
    2,611
    Gender:
    Male
    Lafayette, LA
    Vehicle:
    '23 DCSB 4x4 SR5
    I saw this thread and went :D

    My dad wanted me to ask my friend how to fix this issue.(sorry pic is sideways...jelly bean android still has bugs on the S2 :p

    Problem is the original pipe comes out of the wall at an angle, not straight. so connect the sink drain the to wall is a bit more tricky...we aren't sure if we should just cut off the pvc and try to make it come straight out..or just figure out how to connect it the way it is..2 90s and a straight piece?...but i see clogging issues if we do that..need suggestions from plumbing gurus :)
    [​IMG]
     
  7. Jul 31, 2012 at 4:30 AM
    #387
    Rusty 06 4x4

    Rusty 06 4x4 [OP] NBHNC

    Joined:
    Sep 26, 2011
    Member:
    #64142
    Messages:
    2,191
    Gender:
    Male
    First Name:
    Rusty
    West Georgia
    Vehicle:
    2006 4x4 Tacoma TRD DCSB
    yes you can cut it and make it come out straight. just have to cut as close to the back side of the angle fitting as possible then go buy a 1 1/2 inch fitting with male threads on it and glue in on and you can push that into there and use the nut you have on that chrome plated brass pipe to screw on to the new adapter
     
  8. Jul 31, 2012 at 4:39 AM
    #388
    Rusty 06 4x4

    Rusty 06 4x4 [OP] NBHNC

    Joined:
    Sep 26, 2011
    Member:
    #64142
    Messages:
    2,191
    Gender:
    Male
    First Name:
    Rusty
    West Georgia
    Vehicle:
    2006 4x4 Tacoma TRD DCSB
    yep that^^^^
     
  9. Aug 15, 2012 at 1:19 PM
    #389
    surfsupl

    surfsupl Well-Known Member

    Joined:
    Jan 8, 2008
    Member:
    #4161
    Messages:
    8,592
    Gender:
    Male
    First Name:
    Gregg
    WestCoast
    Vehicle:
    I DONT CARE IF IT'S A RE-POST
    Rear Diff Breather~ 5100's ~Fog Light Anytime~Tint~TRD Seat Covers~Weather Tech's~Pioneer H.U.~Lift~Eibach Springs~LED's......blah...blah...blah
    I recently changed out my price pfister valves in one of my rental units.(tub/shower) They come with new seats of course and I installed them. They look to be brass but a guy I know is trying to tell me steel seats are better. Is their any truth to this. We do have hard water so I dont know if that makes a difference?

    Thanks
     
  10. Aug 15, 2012 at 1:58 PM
    #390
    Kolunatic

    Kolunatic Broke ass

    Joined:
    Apr 29, 2012
    Member:
    #77862
    Messages:
    46,732
    Gender:
    Male
    First Name:
    Kevin
    Texas
    Vehicle:
    07 DC peerunner
    If ya can find monel,then get it. Brass seats won't last long,but they'll work.
     
  11. Aug 15, 2012 at 2:28 PM
    #391
    surfsupl

    surfsupl Well-Known Member

    Joined:
    Jan 8, 2008
    Member:
    #4161
    Messages:
    8,592
    Gender:
    Male
    First Name:
    Gregg
    WestCoast
    Vehicle:
    I DONT CARE IF IT'S A RE-POST
    Rear Diff Breather~ 5100's ~Fog Light Anytime~Tint~TRD Seat Covers~Weather Tech's~Pioneer H.U.~Lift~Eibach Springs~LED's......blah...blah...blah
    This site contains affiliate links for which the site may be compensated.
  12. Aug 15, 2012 at 2:30 PM
    #392
    surfsupl

    surfsupl Well-Known Member

    Joined:
    Jan 8, 2008
    Member:
    #4161
    Messages:
    8,592
    Gender:
    Male
    First Name:
    Gregg
    WestCoast
    Vehicle:
    I DONT CARE IF IT'S A RE-POST
    Rear Diff Breather~ 5100's ~Fog Light Anytime~Tint~TRD Seat Covers~Weather Tech's~Pioneer H.U.~Lift~Eibach Springs~LED's......blah...blah...blah
    I was reading Price Pfister's info on their seats they claim they are steel seats with a brass finish. Who knows? Going to order some steel bibb seats
     
  13. Aug 15, 2012 at 5:18 PM
    #393
    Kolunatic

    Kolunatic Broke ass

    Joined:
    Apr 29, 2012
    Member:
    #77862
    Messages:
    46,732
    Gender:
    Male
    First Name:
    Kevin
    Texas
    Vehicle:
    07 DC peerunner
    Vice foster never ceases to amaze me.I usually only find they're stuff at home depot.
    I did install they're Roman tub valve in my bathroom cuz it saved me a few hundred bucks. Was still the old delta design.
     
  14. Sep 6, 2012 at 8:13 AM
    #394
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    I'm preparing to replace my 100 year old galvanized with copper (3/4" in this instance). I want to install the copper up in my floor joists (2" x 8").

    My plumber says to drill a 1" hole 5 1/4" down from the top of the joist. Assuming the hole is 1" and 5 1/4" down, this will leave me with 1 3/4" of solid wood under the joist. Actual size of the joist is 1 1/2" x 7 1/2".

    Does this sound about right?
    Thanks
     
  15. Sep 24, 2012 at 5:36 AM
    #395
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    No comments? That could make sense :)
     
  16. Sep 24, 2012 at 5:43 AM
    #396
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    I'm putting in a new water heater soon. I have a permit and will be required to do a rough-in and final inspection. My plumber will do the gas and vent work. I'll do the water lines and dedicated 15 amp service for the new direct vent water heater.

    I'm wondering about these flexible copper and gas lines that attach directly to the water heater. My friends like them, as it makes final hookup a lot easier.

    But that seems to me to create a weak link and that it is better to run straight pipe to the water heater? Copper will be used with unions. What are your thoughts on this?

    Thanks so much
     
  17. Sep 24, 2012 at 6:23 AM
    #397
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    flex is fine....
    better in most locations
    if something moves it will not break your gas lines.....
    other wise you would have alot of hard piping to do to make it seismic proof
     
  18. Sep 24, 2012 at 6:24 AM
    #398
    brutalguyracing

    brutalguyracing BIG DADDY

    Joined:
    Jun 28, 2009
    Member:
    #19000
    Messages:
    24,052
    Gender:
    Male
    F.U> GUYZ
    broken mods
    sounds about right as the load is directed at the top of said joist
    might want to ask a real carpenter "not oz":D just to double check
     
  19. Sep 24, 2012 at 6:48 AM
    #399
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    Makes sense, thanks!
     
  20. Sep 25, 2012 at 5:45 AM
    #400
    Geode

    Geode Well-Known Member

    Joined:
    Sep 22, 2009
    Member:
    #23175
    Messages:
    267
    Gender:
    Male
    Illinois
    Vehicle:
    09 4WD TRD
    As you recall I put in a new 1" copper water main last spring. My water meter is a 3/4" by 5/8". I need to run new copper from my main to the new water heater.
    It has been suggested that using 3/4" copper is fine. My branches will attach during this run. I'm curious what you think about this, and if I should run this main branch as 1" copper instead?

    I know the meter will limit the flow to some degree. I've read that a 3/4" trunk line can supply three 1/2" branches.
     

Products Discussed in