Discussion in '2nd Gen. Tacomas (2005-2015)' started by Cashw76, Sep 26, 2022.

  1. Sep 26, 2022 at 6:14 AM
    #1
    Cashw76

    Cashw76 [OP] Member

    Joined:
    Oct 5, 2019
    Member:
    #307172
    Messages:
    6
    Having a issue with my 2010 tacoma. Over the past week my AC/Heat has stopped blowing in my truck. I have checked all the fuses and replace the blower motor resistor as well as dropping the blower motor and testing it out and it was fine. Any idea what the issue could be?
     
  2. Sep 26, 2022 at 6:16 AM
    #2
    CTSpruceMica

    CTSpruceMica Is a hotdog a sandwich?

    Joined:
    Sep 8, 2020
    Member:
    #340174
    Messages:
    5,736
    First Name:
    Dennis
    Vehicle:
    2014 Spruce Mica
  3. Sep 26, 2022 at 6:35 AM
    #3
    Cashw76

    Cashw76 [OP] Member

    Joined:
    Oct 5, 2019
    Member:
    #307172
    Messages:
    6
    Thank you, another question if you don't mind if this is what's causing the issue would the defrost still be working that's is the only thing that is working at the moment.
     
  4. Sep 26, 2022 at 6:44 AM
    #4
    Dm93

    Dm93 Test Don't Guess

    Joined:
    Mar 3, 2015
    Member:
    #150066
    Messages:
    13,911
    Gender:
    Male
    Texas
    Vehicle:
    2014 DC OR 6spd 4x4
    Predator tube steps, Ranch Hand grill guard, Magnaflow CatBack exhaust, Toyota tool box & bed mat, 2LO Module by @Up2NoGood, Rearview Compass/Temp Mirror, Tune by @JustDSM.
    So is it blowing air but not out the vents or is it not blowing at all?
     
  5. Sep 26, 2022 at 6:45 AM
    #5
    Cashw76

    Cashw76 [OP] Member

    Joined:
    Oct 5, 2019
    Member:
    #307172
    Messages:
    6
    It's not blowing out of the vents at all the only place that seems to be blowing is when I have the heat on and the defrost. Another than that it's not blowing from any vents.
     
  6. Sep 26, 2022 at 6:49 AM
    #6
    CTSpruceMica

    CTSpruceMica Is a hotdog a sandwich?

    Joined:
    Sep 8, 2020
    Member:
    #340174
    Messages:
    5,736
    First Name:
    Dennis
    Vehicle:
    2014 Spruce Mica
    A blend door problem can cause air flow from "wrong" vents, i.e. different than the control setting.
     
    Cashw76[QUOTED][OP] likes this.
  7. Sep 26, 2022 at 7:01 AM
    #7
    Cashw76

    Cashw76 [OP] Member

    Joined:
    Oct 5, 2019
    Member:
    #307172
    Messages:
    6
    Alright thank you I will try that out.
     
  8. Sep 26, 2022 at 7:20 AM
    #8
    Dm93

    Dm93 Test Don't Guess

    Joined:
    Mar 3, 2015
    Member:
    #150066
    Messages:
    13,911
    Gender:
    Male
    Texas
    Vehicle:
    2014 DC OR 6spd 4x4
    Predator tube steps, Ranch Hand grill guard, Magnaflow CatBack exhaust, Toyota tool box & bed mat, 2LO Module by @Up2NoGood, Rearview Compass/Temp Mirror, Tune by @JustDSM.
    The actuators can be seen by removing the glovebox and floor duct, the duct is a little tricky to get off but pretty easy once you figure it out.
    [​IMG]

    The notch on the actuator shaft should line up with the mark on the actuator body as shown in the picture below.
    [​IMG]

    Recirc door should also be open as shown with the recirc button on.

    Closed (Recirc off)
    [​IMG]

    Open (Recirc on)
    [​IMG]
     
    Jimmyh, Naveronski and shmn like this.