Blower motor connector fried (07 PreRunner)

Discussion in 'Technical Chat' started by dmanemann, Dec 30, 2011.

  1. Dec 30, 2011 at 4:55 PM
    #1
    dmanemann

    dmanemann [OP] New Member

    Joined:
    Dec 30, 2011
    Member:
    #69659
    Messages:
    2
    Gender:
    Male
    Vehicle:
    07 PreRunner
    Never had a problem with the blower motor or resistor (as others have noted in these forums) in my '07 PreRunner until today when smoke from under the glove-box and the strong smell of burning plastic forced me to pull off to the side of the road.

    When taking out the blower motor tonight I noticed that the female connector was fried on one side and contained one of the two electrical prongs that was formerly attached to the motor. I know where I can get a new blower motor but can't seem to find a part number for the connector. I'm assuming that I can splice a new connector into the harness.

    Can anyone tell me where I can find that part number, better yet a place where I can order it? Other suggestions for a fix?
     
  2. Dec 30, 2011 at 5:06 PM
    #2
    NelsonTacoma

    NelsonTacoma This is my derpawayinator!!!!!

    Joined:
    Mar 25, 2010
    Member:
    #33969
    Messages:
    2,081
    Gender:
    Male
    Tucson, AZ
    Vehicle:
    06 PreRunner TRD Sport 03 4Runner Limited 4wd
    Bilstein 5100's , 6000k HID Hi/Low Kit, Magnaflow Muffler, 1.5 inch AP Wheel Spacers, Mudflap Delete
  3. Dec 30, 2011 at 5:44 PM
    #3
    dmanemann

    dmanemann [OP] New Member

    Joined:
    Dec 30, 2011
    Member:
    #69659
    Messages:
    2
    Gender:
    Male
    Vehicle:
    07 PreRunner
    Thanks for the post, NelsonTacoma. I seen those connectors in my search but neither matched the connector I'm looking for. I've attached images of both blower and connector.

    blower_sm.jpg
    connector_sm.jpg
     
  4. Jun 11, 2013 at 1:05 PM
    #4
    stva1006

    stva1006 New Member

    Joined:
    Jun 11, 2013
    Member:
    #106052
    Messages:
    1
    Gender:
    Male
    I was wondering if you were ever able to locate the part number for the connector? Same thing happened to my '07 after 6 years being problem free!
     
  5. Aug 30, 2013 at 2:44 PM
    #5
    TSlagle

    TSlagle New Member

    Joined:
    Dec 12, 2011
    Member:
    #68630
    Messages:
    3
    Gender:
    Male
    dmanemann, Stva1006,

    Any luck finding the blower motor connector? Have a 2010, same problems as others. Connector fried.
     
  6. Aug 17, 2014 at 3:32 PM
    #6
    Chuy

    Chuy Well-Known Member

    Joined:
    Aug 4, 2008
    Member:
    #8328
    Messages:
    3,446
    Gender:
    Male
    Lakeside, CA
    Vehicle:
    07 V6 DCLB 4X4 Sport
    Silver Taco
    This same thing happened on my 2007 4-door 4X4 back in April of this year.

    My initial problem was the blower only working on the high setting. A new resistor late last year fixed that problem, but then the blower stopped blowing altogether. I worked the problem to the blower connector. The connector had melted and the plastic insulation on the wires at the connector had melted off about 2 inches. I had to cut the blower wires in order to remove the blower and take it to my bench. I was able to cut off enough material to remove the connector. Lucky for me the two tabs in the blower were intact and the connector, although partly melted and burnt, appeared functional. I notice the connector moved in/out too easy when inserting into the blower connector; this loose connection may have caused the overheating. I cleaned the tabs and used a pick to press the female tabs in the connector for a tighter fit.

    I looked for a new connector but I did not find one. I did order some tabs to be on standby in case the connector melts again on me in the future. The tabs are .187 12-10 gauge female disconnects. I "dry-fitted" them and they could get the job done if needed. You only have to glue a spacer to keep the disconnects from making contact with each other. So far, my fix is holding up. All my blower speeds work again, but the wires down there still heat up a bit. I'm still looking for a new connector.

    So guys, with the blower on high for a couple of minutes, touch those two wires at the connector and see if they are not too hot. If they are, you may want to remove the connector and crimp the female tabs a little tighter to provide a more secure connection.

    IMG_0593[1].jpg
    IMG_0594[1].jpg
     
    Last edited: Aug 17, 2014
  7. Jan 1, 2015 at 9:47 AM
    #7
    lelio98

    lelio98 New Member

    Joined:
    Jan 1, 2015
    Member:
    #145345
    Messages:
    2
    Gender:
    Male
    First Name:
    Shane
    California
    Were you ever able to locate the correct connector? Mine has completely melted away!
     
  8. Jan 11, 2015 at 4:38 PM
    #8
    TSlagle

    TSlagle New Member

    Joined:
    Dec 12, 2011
    Member:
    #68630
    Messages:
    3
    Gender:
    Male
    Lelio98,

    Yes, I was able to repair. I wound up at the local Toyota dealership. I could not locate a new or used anywhere....The parts guy was great, he looked in the back and found a connector that was not fried. I did purchase a new resistor. From what I researched...The factory resistor was bad, that caused the connector to fry.
     
  9. Feb 16, 2016 at 7:57 AM
    #9
    ajb1371

    ajb1371 Member

    Joined:
    Feb 8, 2016
    Member:
    #177591
    Messages:
    16
    Gender:
    Male
    Vehicle:
    2010 Black DCLB 4x4
    Here's my situation...

    I have a short in mine somewhere... The zip tie was pulling the cord, allowing the heater to work. Any ideas or I am stuck with going to the dealership??

    63921.jpg
     
  10. Apr 30, 2017 at 2:35 PM
    #10
    cookswv

    cookswv New Member

    Joined:
    Apr 30, 2017
    Member:
    #217752
    Messages:
    1
    Has anyone found this connector? Same one I need and can't find
     
  11. May 17, 2017 at 11:45 AM
    #11
    Johnkr

    Johnkr New Member

    Joined:
    May 17, 2017
    Member:
    #219259
    Messages:
    1
    Gender:
    Male
    First Name:
    John
    Vehicle:
    2010 Tacoma
    My son has a 2010 Tacoma and the blower motor connector was burned, this is the connector on the fan a two wire connector, not the one that connects to the little resistor board!
    The dealer said you need to buy the whole harness, but you can buy the connector separate and the two wires each separate with the female pins already crimped.
    Housing Connector 90980-10916
    Wire with terminals 82998-12380 need two !
     
  12. Jul 10, 2018 at 9:11 PM
    #12
    WiredPig

    WiredPig Member

    Joined:
    Mar 6, 2018
    Member:
    #246543
    Messages:
    11
    Gender:
    Male
    First Name:
    Glenn
    Forest Grove, OR
    Vehicle:
    2006 Tacoma PreRunner DCLB
    USB Outlets In Cab.
    Thanks for the thread. I just ran into this on my '06 PreRunner. I pulled the connector and looked at it, sure thing, its burnt. Time to get a new blower motor, connector and terminals.
     
  13. Jul 11, 2018 at 2:58 PM
    #13
    stefanlg55

    stefanlg55 Toyota Master Technician

    Joined:
    Jan 27, 2018
    Member:
    #242605
    Messages:
    195
    Gender:
    Male
    Vehicle:
    2008 Tacoma TRD OffRoad
    Yep these are the correct part numbers!!
     
  14. Jul 20, 2018 at 1:10 PM
    #14
    WiredPig

    WiredPig Member

    Joined:
    Mar 6, 2018
    Member:
    #246543
    Messages:
    11
    Gender:
    Male
    First Name:
    Glenn
    Forest Grove, OR
    Vehicle:
    2006 Tacoma PreRunner DCLB
    USB Outlets In Cab.
    Anyone know what the motor's amp rating is? I'm going to put in an inline fuse.
     
  15. Aug 21, 2018 at 8:08 PM
    #15
    ColoTacoPrerunner06

    ColoTacoPrerunner06 Truck of my dreams

    Joined:
    Jul 22, 2018
    Member:
    #260095
    Messages:
    281
    Gender:
    Male
    Vehicle:
    Speedway Blue 06 Prerunner built like I like it.
    5.5 lift front 4 rear on 33s with an endless amount more work to do
    Different aftermaket suppliers will have different amp ratings. Check their websites. But this issue is usually because the blower motor gets worn and generates too much heat from the excessive draw. This circuit does have an adequate fuse. The issue is that the start up amperage is higher than the running amperage. So if you put a low amp fuse rated at the running amperage it will blow everytime you turn the fan on. Especially if your like me and tend to go from off to max speed.
     
  16. Aug 22, 2018 at 3:06 AM
    #16
    80schild

    80schild Well-Known Member

    Joined:
    Apr 26, 2017
    Member:
    #217412
    Messages:
    623
    Gender:
    Male
    First Name:
    Chad
    Flori-Bama
    Vehicle:
    2007 TRD Sport Access Cab
    So for those of us who haven’t had this issue (yet), do you think it’s best to go ahead and replace the motor before this happens?
     
  17. Aug 22, 2018 at 8:41 AM
    #17
    ColoTacoPrerunner06

    ColoTacoPrerunner06 Truck of my dreams

    Joined:
    Jul 22, 2018
    Member:
    #260095
    Messages:
    281
    Gender:
    Male
    Vehicle:
    Speedway Blue 06 Prerunner built like I like it.
    5.5 lift front 4 rear on 33s with an endless amount more work to do
    Just replace it when it starts to make noise before it gets too loud
     
  18. Jun 3, 2023 at 10:43 AM
    #18
    JeffBoyardee

    JeffBoyardee Well-Known Member

    Joined:
    Mar 26, 2019
    Member:
    #288021
    Messages:
    768
    Gender:
    Male
    First Name:
    Jeff
    Seminole, FL
    Vehicle:
    2011 TRD Off-Road Tacoma DCSB
    Resurrecting an oooollllld thread.

    Both of these items look like they have the plug, with wires attached. What am I missing?

    I noticed mine is starting to get a little burnt, so I want to order the parts to get ahead of it.
     