Replaced blower motor and resistor, same problem

Discussion in '2nd Gen. Tacomas (2005-2015)' started by Dcwn.45, Dec 5, 2018.

  1. Dec 5, 2018 at 6:17 PM
    #1
    Dcwn.45

    Dcwn.45 [OP] Well-Known Member

    Joined:
    Mar 27, 2017
    Member:
    #214502
    Messages:
    95
    Gender:
    Male
    First Name:
    David
    Vehicle:
    2013 dcsb trd off road
    OME suspension ARB front bumper Warn M8000
    About a year ago my 2013 Tacoma's blower motor suddenly worked only on high.
    After searching this forum, I got the new connector and resistor and it worked perfectly.
    For about a year.
    At first it was intermittent then only high speed.
    The parts store guy told me that it's likely the blower fan failing which is causing it to burn up resistors and I should replace both.
    This was corroborated by my son in law , a mechanic, who I had replace the parts.
    problem solved, for about a week, and the same thing happened.
    He thought maybe a loose connection, took it apart, put some grease on the connector, and it worked fine.
    for another week.
    Now it's doing the same thing , he thought maybe a defective resistor, got a new one but this time it didn't fix it.
    Any ideas?
    maybe the dash switch?
     
  2. Dec 5, 2018 at 6:53 PM
    #2
    Taco'09

    Taco'09 Well-Known Member

    Joined:
    Dec 31, 2008
    Member:
    #12073
    Messages:
    1,825
    Gender:
    Male
    OP, can you take a pic of the connector at the resistor and post it? Take the two halves apart. I would like to see if there are signs of over heating the terminals. The thing is the terminals in connector have been known to have weak spring force against one another and that ramps up the resistance, gets hot and the terminals make poor contact.
     
    balljoint likes this.
  3. Dec 5, 2018 at 7:34 PM
    #3
    Pork Chopper

    Pork Chopper Well-Known Member

    Joined:
    Dec 5, 2014
    Member:
    #143709
    Messages:
    408
    Gender:
    Male
    Dallas, TX
    Vehicle:
    07 DC 4x4
    I’ve replaced my connector and pins twice, but never the resistor. IIRC when mine would burn up, the female pins would sort of widen and not make full contact. First one lasted about 3 years, second one has a year on it.

    Edit: I could wiggle the plug and all speeds would work, which told me it wasn’t making good contact.
     
    Last edited: Dec 5, 2018
    Shaggs likes this.
  4. Dec 5, 2018 at 7:47 PM
    #4
    Jimmyh

    Jimmyh Well-Known Member

    Joined:
    May 16, 2012
    Member:
    #78991
    Messages:
    13,749
    Gender:
    Male
    SC
    Vehicle:
    2012 Prerunner SR5
    Torspd, robm7, knayrb and 3 others like this.
  5. Dec 6, 2018 at 4:25 AM
    #5
    Dcwn.45

    Dcwn.45 [OP] Well-Known Member

    Joined:
    Mar 27, 2017
    Member:
    #214502
    Messages:
    95
    Gender:
    Male
    First Name:
    David
    Vehicle:
    2013 dcsb trd off road
    OME suspension ARB front bumper Warn M8000
    Good info,thanks
     
  6. Dec 7, 2018 at 11:53 AM
    #6
    Dcwn.45

    Dcwn.45 [OP] Well-Known Member

    Joined:
    Mar 27, 2017
    Member:
    #214502
    Messages:
    95
    Gender:
    Male
    First Name:
    David
    Vehicle:
    2013 dcsb trd off road
    OME suspension ARB front bumper Warn M8000
    I looked at the connector for the blower and it is tight and has no signs of being burnt.
    Any ideas what to check next?
     
  7. Dec 7, 2018 at 11:58 AM
    #7
    balljoint

    balljoint Well-Known Member

    Joined:
    Feb 14, 2015
    Member:
    #148680
    Messages:
    1,302
    First Name:
    Dave
    Ontario
    Vehicle:
    '18 DCLB
    This has been written up before on this website.

    On my ‘05 I replaced the resistor and the problem came back. I eventually disassembled the connector and slid the spade connectors right into place and pinched them. They were perfect ever after. The connectors get shitty and loose and that was the problem with mine. It doesn’t matter how tight the plastic of the connector is right now. The heat can help cause oxide build up on the actual spade part.

    They are in an area which is subject to getting kicked by passengers who are rarely as careful with your super cool truck as you are.
     
    TomTwo, Jimmyh and Freeheelbillie like this.
  8. Dec 7, 2018 at 3:54 PM
    #8
    Dcwn.45

    Dcwn.45 [OP] Well-Known Member

    Joined:
    Mar 27, 2017
    Member:
    #214502
    Messages:
    95
    Gender:
    Male
    First Name:
    David
    Vehicle:
    2013 dcsb trd off road
    OME suspension ARB front bumper Warn M8000
    Thanks, I will try that.
     
  9. Dec 7, 2018 at 4:24 PM
    #9
    maineah

    maineah Well-Known Member

    Joined:
    Mar 24, 2011
    Member:
    #53641
    Messages:
    6,585
    Gender:
    Male
    First Name:
    Tim
    Maine
    Vehicle:
    4X4 SR5 V6 6spd
    High speed does not go thru the resistor.
     
    Jimmyh likes this.
  10. Dec 7, 2018 at 4:40 PM
    #10
    Jimmyh

    Jimmyh Well-Known Member

    Joined:
    May 16, 2012
    Member:
    #78991
    Messages:
    13,749
    Gender:
    Male
    SC
    Vehicle:
    2012 Prerunner SR5
  11. Dec 7, 2018 at 6:49 PM
    #11
    zippythepinhead

    zippythepinhead Member

    Joined:
    Aug 9, 2011
    Member:
    #61454
    Messages:
    21
    Gender:
    Male
    Vehicle:
    2008 Double Cab RWD
    Similar problem here, just today the blower stopped working completely on all speeds. I pulled the two connectors in the photo below and there was no burning or damage as I have seen in other threads. The vehicle is a 2008 Tacoma. What should I be checking next?

    [​IMG]
     
  12. Dec 8, 2018 at 5:16 AM
    #12
    maineah

    maineah Well-Known Member

    Joined:
    Mar 24, 2011
    Member:
    #53641
    Messages:
    6,585
    Gender:
    Male
    First Name:
    Tim
    Maine
    Vehicle:
    4X4 SR5 V6 6spd
    The motor comes out easley you might want to see if it actually turns easily by hand. Once it's out probe the two terminals with a voltmeter see if you have voltage there with the fan switch on. About a month ago I had to remove the motor in my 2011 because it squealed like a pig from dry bushings left alone it probably would have seized. If it turns hard likely as not It won't work on low speeds the only thing that will happen is the resistors will get hot and there is a good chance they are all ready cooked.
     
    Last edited: Dec 8, 2018
  13. Dec 8, 2018 at 6:20 AM
    #13
    balljoint

    balljoint Well-Known Member

    Joined:
    Feb 14, 2015
    Member:
    #148680
    Messages:
    1,302
    First Name:
    Dave
    Ontario
    Vehicle:
    '18 DCLB
    The motors do get cooked by the shitty resistor connectors. I did replace my blower motor as well early in but the problems didn’t stop until I got rid of the connector and effectively hard wired it. The motors are not expensive from the dealer and are easy to install.

    On a non op fan first check should be fuses.
     
  14. Dec 8, 2018 at 3:13 PM
    #14
    zippythepinhead

    zippythepinhead Member

    Joined:
    Aug 9, 2011
    Member:
    #61454
    Messages:
    21
    Gender:
    Male
    Vehicle:
    2008 Double Cab RWD
    OK, I put a voltmeter on the plug for the motor and I'm getting voltage there when I'm on various fan speeds. So I assume the motor is dead. I see many choices for a replacement, all the way from $29 (Rock Auto) to $125 (Amazon OEM). Any recommendations?
     
  15. Dec 9, 2018 at 8:46 AM
    #15
    Pork Chopper

    Pork Chopper Well-Known Member

    Joined:
    Dec 5, 2014
    Member:
    #143709
    Messages:
    408
    Gender:
    Male
    Dallas, TX
    Vehicle:
    07 DC 4x4
    Rock Auto is strictly online and you can not call them, not even their customer service. Not a big deal unless you have to return something.
     
  16. Dec 9, 2018 at 9:48 PM
    #16
    Shaggs

    Shaggs Well-Known Member

    Joined:
    Feb 26, 2012
    Member:
    #73708
    Messages:
    1,892
    Gender:
    Male
    First Name:
    Matt
    NorCal
    Vehicle:
    2012 DoubleCab Long Bed 4x4 TRD Magnetic Gray
    It's usually the resistor, they go out all the time.
     
  17. Dec 10, 2018 at 6:25 AM
    #17
    Troyken

    Troyken Well-Known Member

    Joined:
    Mar 23, 2015
    Member:
    #151577
    Messages:
    590
    Gender:
    Male
    NY
    Vehicle:
    2013 DCSB v6 off road 4x4 6 spd. MT
    Please verify that you do not have water leaking into the blower housing via the cabin air filter. You may replace the motor only to have it fail again.
     
    zippythepinhead likes this.
  18. Dec 10, 2018 at 7:15 AM
    #18
    jross20

    jross20 Well-Known Member

    Joined:
    Feb 19, 2018
    Member:
    #244913
    Messages:
    2,028
    Gender:
    Male
    First Name:
    John
    Georgia
    Vehicle:
    2000 4Runner SR5 4x4 | V6 | Auto
    Tundra 5100s F+R, OME 880s+890s, duro bumps, etc
    The blower motor? All 3 dealers around me sell them for $200! I got mine on amazin for $135.
    Neither are cheap...haha.
     
  19. Dec 10, 2018 at 7:58 AM
    #19
    balljoint

    balljoint Well-Known Member

    Joined:
    Feb 14, 2015
    Member:
    #148680
    Messages:
    1,302
    First Name:
    Dave
    Ontario
    Vehicle:
    '18 DCLB
    I would still count $200 and a couple of beers with of labour as a cheap fix. Lots more expensive stuff that you can break.
     
  20. Dec 10, 2018 at 11:10 AM
    #20
    jross20

    jross20 Well-Known Member

    Joined:
    Feb 19, 2018
    Member:
    #244913
    Messages:
    2,028
    Gender:
    Male
    First Name:
    John
    Georgia
    Vehicle:
    2000 4Runner SR5 4x4 | V6 | Auto
    Tundra 5100s F+R, OME 880s+890s, duro bumps, etc
    Not for how often they seem to fail. Though thankfully the 44 revision has a bolt so I can take her apart to oil the crappy bearing.

    If anyone has a squeky one try to oil it if you can!
     
To Top