Warn M8000-S wiring - is it undersized out of the box?

Discussion in 'Technical Chat' started by turbodb, Aug 14, 2016.

  1. Aug 14, 2016 at 1:06 PM
    #1
    turbodb

    turbodb [OP] AdventureTaco

    Joined:
    Feb 9, 2016
    Member:
    #177696
    Messages:
    7,804
    Gender:
    Male
    First Name:
    Dan
    PNW
    Vehicle:
    2000 Tacoma Xcab 4x4 SR5 V6 TRD
    AdventureTaco
    Hopefully a simple question, but something that's been bugging me since I bought a Warn M8000-S winch.

    The wiring between the winch, battery, and control box is #2 gauge wire. At varying loads, the winch seems capable of pulling up to 435A. (warn specs, also below)

    m8000 specs.jpg

    Does that mean the wiring is undersized? I thought #2 gauge maxed out in the ~130A range (obviously varying a bit on temp) I must be missing something.

    wiring gauge.jpg

    Thanks!
     
    Last edited: Sep 14, 2016
  2. Aug 14, 2016 at 3:36 PM
    #2
    Wyoming09

    Wyoming09 Well-Known Member

    Joined:
    Apr 24, 2015
    Member:
    #153833
    Messages:
    14,277
    Gender:
    Male
    New Tripoli Pa
    Vehicle:
    2000 Work truck 5 speed 4x4 3.4
    Super Springs
    If you feel it is to small for your use go larger!!

    Quite possible your winch got packed with the wrong cable my old cable is around I will try and see what size it is

    Only you know what kinds of use your going to have

    I can`t recall but I think the Motor overloads would trip before the cable got to warm.

    Now I use 1/0 welding cable to run the winch leads to the rear of my vehicle

    Then I seldom winch down to the last layer of the drum or drag 8000 pounds
     
  3. Aug 14, 2016 at 8:06 PM
    #3
    turbodb

    turbodb [OP] AdventureTaco

    Joined:
    Feb 9, 2016
    Member:
    #177696
    Messages:
    7,804
    Gender:
    Male
    First Name:
    Dan
    PNW
    Vehicle:
    2000 Tacoma Xcab 4x4 SR5 V6 TRD
    AdventureTaco
    I'm actually just referencing the specs of the wiring from the Warn site. (I've verified that's the cable size in the box too - it's not that it was packed wrong.) With Warn being the top end of winching, I figured they'd provide a system that was up to spec, which is why I assume I'm missing something.
     
  4. Aug 14, 2016 at 8:12 PM
    #4
    bzzr2

    bzzr2 Well-Known Member

    Joined:
    Jan 26, 2011
    Member:
    #49986
    Messages:
    2,060
    Gender:
    Male
    i run the warn m8000-s and have put it to the test many times since picking it up last spring. i feel that the wiring included is up to where it needs to be as i've run the winch really hard and never had any issues with power or heat.
     
  5. Aug 16, 2016 at 8:18 PM
    #5
    turbodb

    turbodb [OP] AdventureTaco

    Joined:
    Feb 9, 2016
    Member:
    #177696
    Messages:
    7,804
    Gender:
    Male
    First Name:
    Dan
    PNW
    Vehicle:
    2000 Tacoma Xcab 4x4 SR5 V6 TRD
    AdventureTaco
    So, I sent email to Warn to see what they'd say. TL;DR: the 2 gauge wiring is fine for the M8000-S application. More details below, read top to bottom. I should also say that I was impressed with their responsiveness.

    ----

    To: Warn Customer Service <cs@warn.com>
    Subject: Support: Wiring on M8000-S Winch

    Hi, I notice that the M800-S has 2 gauge wire, but I also notice that it's specs state a pull up to 435A at full load. It seems to me that that means the wire may be undersized. Am I misunderstanding something? Is the wire sized correctly?
    Thanks!

    ----------------------------------------------------------------------
    From: Warn Customer Service

    Yes the wire is sized appropriately for the winch as it’s only a intermittent use item.
    Regards,
    WARN INDUSTRIES INC.

    ------------------------------------------------------------------
    To:
    Warn Customer Service

    Thanks for getting back to me. I think I’ve got it. What you’re saying is that in a situation like this, where usage duration of the winch is measured in seconds/low minutes at a time, the wire may heat up/be less efficient than a larger diameter wire, but that’s fine so long as the usage duration doesn’t cause significant overheating (and thus melting of insulation, etc.)

    Does that sound right?

    Cheers!
    ------------------------------------------------------------------
    From:
    Warn Customer Service

    That sounds exactly correct.


    Regards,
    WARN INDUSTRIES INC.


     
    Mech_Eng likes this.